(21 intermediate revisions by 5 users not shown) |
Line 1: |
Line 1: |
| <small>Return to [[ReleaseEngineering:Sheriffing]]</small>
| | See [[ReleaseEngineering:Buildduty]] |
| | |
| This page serves as a clearinghouse of information on how to perform the various duties associated with buildduty.
| |
| | |
| __TOC__
| |
| | |
| = Try Server =
| |
| == How do I trigger a talos run for a given try build? ==
| |
| * When someone pings you in #build with their try run dir name (format: $email-$changeset eg: lsblkk@mozilla.org-4asf23fsd251d):
| |
| *Either:
| |
| **ssh into production-master{01,02,03}
| |
| **OR run from your machine tools/buildfarm/maintenance/try_sendchange.py
| |
| ***on the production-masters, there is a ~/try_sendchange.sh wrapper script which uses argparse in /tools/buildbot-0.8.0/bin/python
| |
| | |
| Then run:
| |
| | |
| ./try_sendchange.sh $email-$changeset
| |
| # OR to do custom set of talos suites
| |
| ./try_sendchange.sh $email-$changeset --t scroll,svg,nochrome
| |
| # NOTICE no spaces between comma-separated suite names!
| |
| | |
| *It will spew back to you all the sendchanges it does.
| |
| | |
| == How do I cancel existing jobs? ==
| |
| on pm02, 'history | grep cancell' for sample usage
| |
| | |
| = To loan slaves =
| |
| * change cltbld's and root's password (passwd)
| |
| * change vnc's password (Linux: vncpasswd / Windows: UltraVNC server "admin properties" on bottom right task bar / OSX: Control Panel -> Sharing)
| |
| * disable buildbot from running after reboot (rename buildbot.tac / rename startTalos.bat for Windows)
| |
| * [only for build slaves] remember to remove all .ssh keys
| |
| * provide to developer the IP address, cltbld's password and VNC's password
| |
| | |
| == To change autologin ==
| |
| * start -> run -> control userpasswords2
| |
| ** (on w7, start -> Search programs and files -> netplwiz)
| |
| * check the option “Users must enter a user name and password to use this computer”
| |
| * apply
| |
| * uncheck the option “Users must enter a user name and password to use this computer”
| |
| * apply
| |
| * account: cltbld, enter new password twice
| |
| | |
| = Dealing with machines =
| |
| * The current downtime bug should always be aliased as "releng-downtime": http://is.gd/cQO7I
| |
| * The current machine reboots bug should always be aliased as "reboots": http://is.gd/dqSV0
| |
| ==Mobile==
| |
| ===n810s===
| |
| Once a device hits a hard state (100% of retries), it is dead. Please use [https://bugzilla.mozilla.org/enter_bug.cgi?alias=&assigned_to=server-ops%40mozilla-org.bugs&blocked=588156&bug_file_loc=http%3A%2F%2F&bug_severity=normal&bug_status=NEW&cc=release%40mozilla-org.bugs&comment=Please%20reimage%20the%20following%20n810s%3A%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-%0D%0Amaemo-n810-&component=Server%20Operations&contenttypeentry=&contenttypemethod=autodetect&contenttypeselection=text%2Fplain&data=&dependson=&description=&flag_type-4=X&flag_type-607=X&form_name=enter_bug&keywords=&maketemplate=Remember%20values%20as%20bookmarkable%20template&op_sys=Maemo&priority=--&product=mozilla.org&qa_contact=mrz%40mozilla.com&rep_platform=ARM&short_desc=Mobile%20Imaging%20-%20n810%20%28YYYY-MM-DD%20%23X%29&status_whiteboard=%5Bmobile%5D%5Breimaging%5D&target_milestone=---&version=other this template] to file a new bug with the device names.
| |
| * 8 devices per bug max
| |
| * if the newest open reimage bug has less then 8 devices, please add to it until it has 8
| |
| * once the newest bug has 8 device in it open a new bug
| |
| * any bug that is resolved should not have any devices added to it
| |
| | |
| == Nagios ==
| |
| * All unacknowledged problems:
| |
| ** https://nagios.mozilla.org/nagios/cgi-bin/status.cgi?host=all&servicestatustypes=28&hoststatustypes=15&serviceprops=10
| |
| * all unacknowledged problems which have notifications enabled:
| |
| ** https://nagios.mozilla.org/nagios/cgi-bin/status.cgi?host=all&servicestatustypes=28&hoststatustypes=15&serviceprops=8202
| |
| * All unacknowledged problems with notifications enabled with HARD failure states (i.e. have hit the retry attempt ceiling):
| |
| ** https://nagios.mozilla.org/nagios/cgi-bin/status.cgi?host=all&servicestatustypes=28&hoststatustypes=15&serviceprops=270346
| |
| | |
| == Coordinate downtime with IT ==
| |
| * Some IT maintenance requires tree closure. Details here: [[ReleaseEngineering:RelEngITSharedDowntime]]
| |
| * If possible, consolidate RelEng and IT downtimes that need tree closures to avoid having two tree closures soon after each other. This is "nice to do", not a "requirement"; if it reduces risk by doing two separate downtimes, thats fine!
| |