Firefox OS/Performance/Power/Sample Delay Calibration of COTS Ammeter

From MozillaWiki
< Firefox OS‎ | Performance‎ | Power
Revision as of 22:53, 17 September 2013 by Dhuseby (talk | contribs) (Created page with "==Calibrating for Initial Sample Dealy of COTS Ammeter== The Yoctopuce Ammeter we're using for the initial baselining of power consumption of Firefox OS has a small delay bef...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Calibrating for Initial Sample Dealy of COTS Ammeter

The Yoctopuce Ammeter we're using for the initial baselining of power consumption of Firefox OS has a small delay before we receive the first sample over the USB connection. This page documents the method used to measure the delay so that we can use it to time-corelate the power usage data with other profiling data for analysis.

Setup and Methodology

I used a Goodfet digital I/O peripheral to toggle on a digital I/O pin and then measure the delay until the ammeter measures current.

Data and Results